MAGUS Epi-FL18T Epi-Fluorescence Illuminator, fluorescence filter cubes B/G/U/V/R
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Ikke på lager
Varen er ikke på lager. Mere info

Udsolgt

Varen er ikke på lager.

Brug funktionen ”Giv mig besked..." herunder for opdateringer.

Leveringsmuligheder  - Vælges ved checkout
GLS - Pakkeshop
Fri fragt
DAO - Hjemmelevering om natten og i de tidlige morgentimer
Perfekt til arbejdsdage - Levering inden kl. 06:00 - Klar når du vågner
9,00
GLS - Levering til hoveddøren
59,00
Afhentning i vores Pick-up point i Ringsted
Fri fragt
DKK 61.099,00
ex. moms 48.879,20
Total inkl. fragt 61.099,00
Giv mig besked når varen er på lager igen
For fluorescence observations on CMO stereomicroscopes

The epi-fluorescence attachment is used to employ the fluorescence technique on a stereomicroscope.
The fluorescence technique is based on the ability of substances to emit light when excited by the light of a certain wavelength. Some specimens exhibit autofluorescence, while others should be treated with fluorochromes.


The attachment is mounted into the optical path between the microscope head and zoom objective. There is a 6-position rotating turret with filters inside the attachment. Five fluorescence filter cubes and a brightfield cube are simultaneously installed in the turret. A set of fluorescence filter cubes includes filters of different fluorescence wavelengths: broadband blue (B), green (G), ultraviolet (U), violet (V), and narrowband red (R). The control unit is used to select the appropriate filter and the brightness of the light source.


The excitation light sources are LEDs. The LEDs instantly reach the brightness that is set by the user. They do not heat up during prolonged use and can switch off quickly, if necessary. This makes it easy to switch from the brightfield technique to fluorescence and back again. The LED lifetime is 50,000 hours. It is recommended to choose LED-based fluorescence for higher education as it is low-maintenance and the safest.


Compatibility:



  • MAGUS Stereo A18T Stereomicroscope


Package:



  • Epi-fluorescence attachment

  • B/G/U/V/R fluorescence filter cubes

  • Control unit

  • UV shield

BrandMAGUS
Warranty2 years
EAN5905555026244
Excitation light sourceLEDs
Fluorescence filter: filter type, excitation wavelength/dichroic mirror/emission wavelength blue (B), 460–495nm / 505nm / 510nm; green (G), 510–550nm / 570nm / 575nm; ultraviolet (U), 330–385nm / 410nm / 420nm; violet (V), 400–410nm / 455nm / 460nm; red (R), 620–650nm / 660nm / 670–750nm